Trigger Configuration (Index=16, RB='1')

Trigger Configuration Register

Register Layout

 

Index=0x10 Byte 0. Index=0x10 Word 0. RB='1'.  

D7 
D6 
D5 
D4 
D3 
D2 
D1 
D0 
ETS3 
ETS2 
ETS1 
ETS0 
STS3 
STS2 
STS1 
STS0 

 

Index=0x11 Byte 1. Index=0x10 Word 0. RB='1'.

D15 
D14 
D13 
D12 
D11 
D10 
D9 
D8 
TEN 
STM1 
STM0 
TSS3 
TSS2 
TSS1 
TSS0 
Bit Definitions
NAME 
DIRECTION 
DEFAULT 
DESCRIPTION 
Don't Care 
TEN 
rw 
Trigger Enable
0 = disabled (default)
1 = enabled 
STM[1:0] 
rw 
00 
Start Trigger Mode.
00 = trigger source (default)
01 = trigger followed by trigger delay
10 = trigger followed by sync followed by trigger delay
11 = Reserved 
TSS[3:0] 
rw 
0000 
Start Trigger Synchronization Source.
0000 = none (default)
0001 = writing 0x5A to the software strobe register
0010 = none
0011 = Analog Input Sample/Frame Timer (Reserve??)
0010 = none
0011 = none
0100 = 8254 Counter 0 Output (CT_OUT0) rising-edge
0101 = 8254 Counter 0 Output (CT_OUT0) falling-edge
0110 = 8254 Counter 2 Output (CT_OUT2) rising-edge
0111 = 8254 Counter 2 Output (CT_OUT2) falling-edge
1000 = DIN0 rising edge
1001 = DIN0 falling edge
1010 = DIN1 rising edge
1011 = DIN1 falling edge
1100 = DIN2 rising edge
1101 = DIN2 falling edge
1110 = DIN3 rising edge
1111 = DIN3 falling edge 
ETS[3:0] 
rw 
0000 
End/Stop Trigger Source
0000 = none (default)
0001 = writing 0xAA to the software strobe register
0010 = Analog Input Frame Maximum
0011 = Analog Input Sample/Frame Timer (Reserve??)
0100 = 8254 Counter 0 Output (CT_OUT0) rising-edge
0101 = 8254 Counter 0 Output (CT_OUT0) falling-edge
0110 = 8254 Counter 2 Output (CT_OUT2) rising-edge
0111 = 8254 Counter 2 Output (CT_OUT2) falling-edge
1000 = DIN0 rising edge
1001 = DIN0 falling edge
1010 = DIN1 rising edge
1011 = DIN1 falling edge
1100 = DIN2 rising edge
1101 = DIN2 falling edge
1110 = DIN3 rising edge
1111 = DIN3 falling edge 
STS[3:0] 
rw 
0000 
Start Trigger Source
0000 = none (default)
0001 = writing 0x55 to the software strobe register
0010 = none
0011 = Analog Input Sample/Frame Timer
0100 = 8254 Counter 0 Output (CT_OUT0) rising-edge
0101 = 8254 Counter 0 Output (CT_OUT0) falling-edge
0110 = 8254 Counter 2 Output (CT_OUT2) rising-edge
0111 = 8254 Counter 2 Output (CT_OUT2) falling-edge
1000 = DIN0 rising edge
1001 = DIN0 falling edge
1010 = DIN1 rising edge
1011 = DIN1 falling edge
1100 = DIN2 rising edge
1101 = DIN2 falling edge
1110 = DIN3 rising edge
1111 = DIN3 falling edge 

Configures the trigger section for a variety of ADC data collection start and stop situations.