You are here: Register Set > Analog Input Frame Timer (Index=36, RB='1')
STX104 Reference Manual
ContentsIndexHome
PreviousUpNext
Analog Input Frame Timer (Index=36, RB='1')

Analog Input Frame Timer Register. Range is 5 uSec to 53.68 Seconds in steps of 25 nanoseconds.

Register Layout

 

Index=0x24 Byte 0. Index=0x24 Word 0. RB='1'.  

D7 
D6 
D5 
D4 
D3 
D2 
D1 
D0 
AIFT7 
AIFT6 
AIFT5 
AIFT4 
AIFT3 
AIFT2 
AIFT1 
AIFT0 

 

Index=0x25 Byte 1. Index=0x24 Word 0. RB='1'.

D15 
D14 
D13 
D12 
D11 
D10 
D9 
D8 
AIFT15 
AIFT14 
AIFT13 
AIFT12 
AIFT11 
AIFT10 
AIFT9 
AIFT8 

 

Index=0x26 Byte 2. Index=0x26 Word 1. RB='1'.

D23 
D22 
D21 
D20 
D19 
D18 
D17 
D16 
AIFT23 
AIFT22 
AIFT21 
AIFT20 
AIFT19 
AIFT18 
AIFT17 
AIFT16 

 

Index=0x27 Byte 3. Index=0x26 Word 1. RB='1'.

D31 
D30 
D29 
D28 
D27 
D26 
D25 
D24 
AIFT31 
AIFT30 
AIFT29 
AIFT28 
AIFT27 
AIFT26 
AIFT25 
AIFT24 
Bit Definitions
NAME 
DIRECTION 
DEFAULT 
DESCRIPTION 
AIFT[31:0] 
rw 
0x00000000 
 

The actual time interval is calculated as: 

 

ADC_Frame_Time = ( AIFT + 1 ) * ( 25 nSec ). 

Where 0 <= AIFT <= 2147483648. 

 

Anything below 5 uSec will be limited by the intra-sample timing which is limited to 5 uSec at a minimum. 

Thus, the ADC frame time is adjustable from 5 microseconds to 53.68 seconds in 25 nanosecond steps. 

 

Range: 5 uSec to 53.68 Seconds. 

Resolution: 25 nanoseconds.

Copyright © 1997-2008 by Apex Embedded Systems. All rights reserved. Updated on Wednesday, April 02, 2008.